Seeing an F.22 Vaillant error code flashing on your boiler display can be frustrating, especially when you’re left without heating or hot water. This fault indicates low water pressure in your system—a common issue that affects thousands of UK homes each year. At Celmeng Group, our experienced heating engineers have diagnosed and resolved countless F.22 faults across Birmingham, and we’re here to help you understand what this error means and how to fix it safely and effectively.
What Does the F.22 Error Code Mean?
The F.22 fault code on Vaillant boilers signals that your system’s water pressure has dropped below the minimum operating level, typically below 0.5 bar. Your boiler requires adequate water pressure to circulate hot water through your radiators and deliver hot water to your taps. When pressure falls too low, the boiler automatically shuts down as a safety measure to prevent damage to internal components.
This protective mechanism exists because running a boiler with insufficient water pressure can cause the heat exchanger to overheat, potentially leading to costly repairs. The good news is that many F.22 faults can be resolved without calling an engineer, though some underlying causes require professional attention.
Common Causes of F.22 Faults
Water System Leaks
The most frequent cause of low water pressure is a leak somewhere in your heating system. Even small leaks can gradually reduce pressure over time, triggering the F.22 error. Leaks commonly occur at:
- Radiator valves and pipe connections
- The boiler’s pressure relief valve
- Towel rails and radiator joints
- Underground pipework (in older properties)
Look for damp patches, water stains, or puddles around radiators, pipes, and your boiler. Sometimes leaks are hidden behind walls or under floorboards, making them harder to detect.
Bleeding Radiators
Regular radiator bleeding releases trapped air but also removes water from the system. If you’ve recently bled multiple radiators without topping up the system pressure afterwards, this could trigger an F.22 fault. Air pockets naturally accumulate in heating systems over time, especially in the upper floors of multi-storey homes.
Faulty Pressure Relief Valve
Your boiler’s pressure relief valve (PRV) protects the system from excessive pressure by releasing water when needed. However, if this valve becomes stuck open or develops a fault, it can continuously discharge water, causing pressure to drop. You might notice water dripping from the overflow pipe outside your home if the PRV is faulty.
Expansion Vessel Problems
The expansion vessel accommodates water expansion as your system heats up. If the vessel loses its pre-charge pressure or develops a fault, it can affect overall system pressure. This is more common in older boilers or systems that haven’t been regularly serviced.
How to Fix an F.22 Fault
Check Your Pressure Gauge
Before attempting any fixes, locate your boiler’s pressure gauge—usually a circular dial with coloured zones. The needle should sit between 1 and 2 bar when the system is cold. If it’s below 1 bar, you’ll need to repressurise the system.
Repressurise Your Boiler
Most Vaillant boilers have a filling loop—a braided hose that connects your mains water to the heating system. Here’s how to safely increase pressure:
- Ensure your boiler is switched off and completely cool
- Locate the filling loop and check both isolation valves are closed
- Slowly open both valves to allow water into the system
- Watch the pressure gauge and close the valves when pressure reaches 1.5 bar
- Remove the filling loop if it’s detachable
- Switch your boiler back on and check the error has cleared
Be careful not to overpressurise the system, as this can trigger different fault codes or cause the pressure relief valve to discharge water.
Inspect for Visible Leaks
Carry out a thorough visual inspection of your heating system. Check all radiators, particularly around valves and pipe connections. Look under your boiler and around the flue for signs of water damage. If you find any leaks, turn off your boiler and contact a qualified heating engineer.
Bleed Your Radiators Properly
If you’ve recently bled radiators, ensure you top up the system pressure afterwards. Always bleed radiators when the heating system is cool, starting with the ground floor and working upwards. After bleeding, check and adjust the boiler pressure as needed.
When to Call a Professional
While simple repressurisation can often resolve F.22 faults, certain situations require professional attention:
Persistent Pressure Loss
If your boiler loses pressure repeatedly despite repressurisation, there’s likely an underlying leak that needs professional diagnosis. Our engineers use specialised equipment to locate hidden leaks and carry out permanent repairs.
Faulty Components
Issues with the pressure relief valve, expansion vessel, or internal boiler components require qualified Gas Safe engineers to diagnose and repair safely. Attempting to fix these problems yourself could be dangerous and may invalidate your boiler warranty.
System Modifications
If your heating system needs modifications, additional radiators, or pipework changes to resolve pressure issues, this work must be carried out by certified professionals to ensure compliance with building regulations.
Preventing F.22 Faults
Regular Boiler Servicing
Annual boiler servicing by a Gas Safe registered engineer helps identify potential problems before they cause breakdowns. During a service, we check system pressure, inspect for leaks, and test safety devices like the pressure relief valve.
Monitor System Pressure
Check your boiler’s pressure gauge monthly, especially during the heating season. Catching pressure drops early prevents the inconvenience of sudden breakdowns and potential damage to your boiler.
Professional Leak Detection
If you notice any signs of leaks—damp patches, water stains, or unexplained pressure loss—contact a qualified engineer promptly. Early intervention often means simpler, less expensive repairs.
Trust the Experts at Celmeng Group
At Celmeng Group, we understand how disruptive boiler faults can be to your daily routine. Our Gas Safe registered engineers have extensive experience with Vaillant boilers and can quickly diagnose and resolve F.22 faults across Birmingham and surrounding areas. Whether you need emergency repairs, annual servicing, or advice on system upgrades, we’re here to help.
Don’t let an F.22 fault leave you without heating and hot water. Contact Celmeng Group on 0121 608 0460 for professional boiler repairs and servicing you can trust. Our experienced team is ready to restore comfort to your home with efficient, reliable solutions.

